Bright Company, Kind People - KAST Engineering

Product

download

home > products > Hipot Tester

Hipot Tester

AC Hipot Tester (Digital)

 

 

This Hipot(puncture) Tester is shows a leakage current on digital meter while test.
Also good, bad, test, enable signal exchange from External equipment, and it is a precision measurement equipment the system connection is easy.

  • Price : 940 (USD)
  • Product model
    • KT-5000PD-20, -50, -100 (output voltage 5 ㎸, current 20, 50, 100 ㎃)
    • KT-10KPD-20, -50, -100 (output voltage 10 ㎸, current 20, 50, 100 ㎃)
    • KT-20KPD-20, -50, -100 (output voltage 20 ㎸, current 20, 50, 100 ㎃)
Explanation about hipot(puncture) tester  

Hipot Test(High Potential Voltage Test) means to test the product wheater there occurs the weakness to the high voltage or remains some materials which reduces electric insulation and the endurance against between 2 points that must be separate. 
This test is done with 2 ~ 5 times higher AC voltage than the operating voltage of the
product - under - test.

Hipot test must be done to all products to figure out the electric insulation for the quality control.

 
Hipot(puncture) tester of KAST

Output voltage Max. current capacity Function & Dimension
0~5 ㎸ AC ( 0 ~ 2.5 ㎸ ) KT-5000PD-20
KT-5000PD-50
KT-5000PD-100
20 ㎃
50 ㎃
100 ㎃
Digital type, Auto judgement, V.A meter
W 420 × H 190 × D 510 (㎜)
0 ~ 10 ㎸ AC ( 0 ~ 5 ㎸ ) KT-10KPD-20
KT-10KPD-50
KT-10KPD-100
20 ㎃
50 ㎃
100 ㎃
Digital type, Auto judgement, V.A meter
W 420 × H 360 × D 640 (㎜)
0 ~ 20 ㎸ AC ( 0 ~ 10 ㎸ ) KT-20KPD-20
KT-20KPD-50
KT-20KPD-100
20 ㎃
50 ㎃
100 ㎃
Digital type, Auto judgement, V.A meter
W 620 × H 1440 × D 720 (㎜)

Common Spec
  1. Power supply : AC 220 V, 50 ~ 60 ㎐
  2. Output voltage : AC 0 ~ 5 ㎸ to (According to model type) 0 ~ 20 ㎸
  3. Current limit set
    1. Max 20 ㎃ : 0.01 ~ 19.99 mA unit by 0.01 ㎃
    2. Max 50 ㎃ : 0.1 ~ 49.9 mA unit by 0.1 ㎃
    3. Max 100 ㎃ : 0.1 ~ 99.9 mA unit by 0.1 ㎃
  4. Output voltage Precision : 0.5 % ± 2 digit
  5. Over current cutoff speed : 50 ms
  6. Output voltage Range(2 Range) : 5 ㎸ / 2.5 ㎸, 10 ㎸ / 5 ㎸, 20 ㎸ / 10 ㎸
  7. Test timer (1 ~ 99 s)
    : The test procedure continues till the timer pointed, which is preset and judges good or bad with bad lamp and
      buzzer until reset button pushed.
     
Merits of KAST's hipot(puncture) tester 
  1. The digital meter displays the leakage current value during the test procedure.  
  2. Function of the real time test.
    : This tester has many I/O ports to make easy to communicate with other test systems.
      (Start, Reset, Busy, Good, Bad, Low error, etc)
      Real time test is a signal input terminal which makes able to proceed the test during the external signal comes
      on to the tester.
     

      When if these terminals are short, test procedure goes on, and if these terminals are off state, test stop. 
      It makes easier mass product test or temporary test stop.
  3. This tesetr has 2 ground lines, and these lines must be to each other just on the product-under-test contacted to stout the test proceed.

    If these 2 ground lines are not contacted to each other, the test procedure stops and low error lamp works.

    The final purpose of this function is to avoid not only the product is judged as good when the ground line is not contacted to the product, but also to alarm the danger of ground open.

  4. This tester does not tuse the pysical ON/OFF switch, but zero cross detect SSR switch, which reduces the unnecessary  noise or impulse.

    And photo couplers are used in all I/O ports(test, start, reset) to decrease the noise too.

  5. Calibration Certificate issued

    : All products that KAST delivered bring out the calibration certificate result together under the rule of ISO
      17025.

 

 

 
  • Model : KT-10KPD-100
  • Digital type
  • Output voltage : 10 ㎸
  • Current limit : Max. 100 ㎃
  • Dimension : W 420 × H 360 × D 640 (㎜)
  • Price : 3,320 (USD)
  • The other spec is same a KT-5000PD

 

 

 


  • Model : KT-3040BDV (KT-20KPD)
  • The available output voltage reaches upto 30 kV, KAST's Hipot Testers are high accracy type.
  • There is a Auto / Manual select switch.

    : If Auto mode is selected, the output voltage comes up/down slowly and the value is displayed.

    And when the current limit is needed to preset, while current preset push button is pused, operator can adjust the current limit value with turning the volume.

    It's easy to preset the current limit value.

  • Power supply : AC 220 V, 50 ~ 60 ㎐
  • Output voltage : 0 ~ 30 ㎸ AC
  • Current limit : Max. 10 ㎃
  • Current limit set range : 0.1 ~ 10.00 ㎃ (Preset)
  • Cutoff Speed : 50 ㎳
  • Power consumption : Approx. 550 W
  • Dimension : W 500 × H 1210 × D 700 (㎜)
  • Net weight : Approx. 90 ㎏
  • Price : 8,640 (USD)


DC Hipot Tester (Digital)

 

 

  • Model : KT-2000PD
  • This hipot(puncture) tester is used DC voltage for hipot(puncture) test, and it is used test of capacitor and cable etc.
  • Power supply : AC 220 V, 50 ~ 60 ㎐
  • Output voltage : 0 ~ 5 ㎸ DC
  • Current limit : Max. 20 mA
  • Setting range of current limit : 0.1 ~ 19.99 ㎃
  • Cutoff speed : ± 40 ㎳
  • Power consumption : Approx. 160 W
  • Good / Bad judge speed : ± 200 ㎳
  • Timer : 1 ~ 99 s (preset)
  • Dimension : W 420 × H 190 × D 550 (㎜)
  • Net weight : Approx. 15 ㎏
  • Price : 1,620 (USD)